Your go-to HPLC columns for separating complex mixtures
Thermo Scientific Acclaim HPLC Columns have a smaller pore size and higher surface area to deliver the high resolution you need for high-efficiency separations. Choose from a broad variety of functional groups including:
- Conventional reversed-phase C18 and polar embedded phases
- Mixed-mode phases
- Application-specific phases
Thermo Fisher Scientific designed and manufactured all Acclaim columns to tight specifications to ensure you get consistent performance.
Acclaim HPLC column families
Column | Use for | Data sheet |
---|---|---|
Acclaim 120 C18 columns | High efficiency reversed-phase columns for small molecule and complex mixtures separations, including LC-MS | Acclaim 120 C18 data sheet |
Acclaim 120 C8 columns | Reversed-phase columns for small molecule with intermediate hydrophobic retention | Acclaim 120 C8 data sheet |
Acclaim 300 C18 columns | Wide pore columns for LC-MS life science applications; protein and peptides | Acclaim 300 C18 data sheet |
Acclaim Polar Advantage (PA) columns | Polar-embedded reversed-phase columns for separating polar and nonpolar analytes with 100% aqueous mobile phase | Acclaim PA data sheet |
Acclaim Polar Advantage (PA2) columns | Polar-embedded columns with enhanced hydrolytic stability pH 1.5 – 10, excellent for polar and non-polar analytes with 100% aqueous mobile phase and LC-MS | Acclaim PA2 data sheet |
Acclaim C30 columns | Very high hydrophobic retention; good for separating structurally related isomers | Acclaim C30 data sheet |
Acclaim HILIC-10 columns | Designed for unique selectivity of hydrophilic molecules |
Specifications for Acclaim reversed-phase & general-purpose HPLC columns | ||||||||
---|---|---|---|---|---|---|---|---|
Acclaim 120 C18 | Acclaim 120 C8 | Acclaim 300 C18 | Acclaim PA | Acclaim PA2 | Acclaim C30 | Acclaim Phenyl-1 | Acclaim HILIC-10 | |
Bonded Phase | Octadecylsilane | Octylsilane | Octadecylsilane | Embedded sulfonamide | Embedded Amide | C30 alkylsilane | Phenyl | Proprietary |
USP Type | L1 | L7 | L1 | L60 | L60 | L62 | L11 | na |
End-capped | Yes | Yes | Yes | Yes | Yes | Proprietary | Yes | |
Starting Material | Ultrapure silica | Ultrapure silica | Ultrapure silica | Ultrapure silica | Ultrapure silica | Ultrapure silica | Ultrapure silica | Ultrapure silica |
Particle Shape | Spherical | Spherical | Spherical | Spherical | Spherical | Spherical | Spherical | Spherical |
Particle Sizes | 2.2 μm, 3 μm, 5 μm | 2.2 μm, 3 μm, 5 μm | 3 μm | 3 μm, 5 μm | 3 μm, 5 μm | 3 μm, 5 μm | 3 μm, 5 μm | 3 μm, 5 μm |
Average Pore Diameter | 120 Å | 120 Å | 300 Å | 120 Å | 120 Å | 200 Å | 120 Å | 120 Å |
Surface Area | 300 m2/g | 300 m2/g | 100 m2/g | 300 m2/g | 300 m2/g | 200 m2/g | 300 m2/g | 300 m2/g |
Total Carbon Content | 18% | 11% | 7% | 17% | 17% |
Column | Use for | Data sheet |
---|---|---|
Acclaim Trinity P1 columns |
| Acclaim Trinity P1 data sheet |
Acclaim Trinity P2 columns |
| Acclaim Trinity P2 data sheet |
Acclaim Mixed-Mode WAX-1 columns |
| Acclaim Mixed-Mode WAX-1 data sheet |
Acclaim Mixed-Mode WCX-1 columns |
| Acclaim Mixed-Mode WCX-1 data sheet |
Acclaim Mixed-Mode HILIC-1 columns |
| Acclaim Mixed-Mode HILIC-1 data sheet |
Specifications for Acclaim mixed-mode HPLC columns | |||||
---|---|---|---|---|---|
Acclaim Trinity P1 | Acclaim Trinity P2 | Acclaim Mixed-Mode WCX-1 | Acclaim Mixed-Mode WAX-1 | Acclaim Mixed-Mode HILIC-1 | |
Functionality | Reversed-phase + weak anion exchange + strong cation exchange | HILIC + strong anion exchange + weak cation exchange | Reversed-phase + weak cation exchange | reversed-phase + weak anion exchange | Reversed-phase + HILIC |
USP Type | n.a. | n.a. | L85 | L78 | n.a. |
Starting Material | Ultra-pure silica | Ultra-pure silica | Ultra-pure silica | Ultra-pure silica | Ultra-pure silica |
Particle Shape | Spherical | Spherical | Spherical | Spherical | Spherical |
Particle Sizes | 3 μm, 5 μm | 3 μm, 5 μm | 3 μm | 3 μm, 5 μm | 3 μm, 5 μm |
Average Pore Diameter | 120 Å | 120 Å | 300 Å | 120 Å | 120 Å |
Surface Area | 300 m2/g | 300 m2/g | 100 m2/g | 300 m2/g | 300 m2/g |
Column | Use for | Data sheet |
---|---|---|
Acclaim Organic Acid HPLC Columns | Fast organic acid analysis; including both aromatic and aliphatic organic acids. | Acclaim Organic Acid data sheet |
Acclaim Surfactant HPLC Columns | Designed for the separation of surfactants including anionic, non-ionic, cationic, and amphoteric surfactants in various matrices. The Surfactant Plus is compatible with LC-MS instrumentation | Acclaim Surfactant data sheet |
Acclaim Surfactant Plus columns | Designed for the separation of surfactants including anionic, non-ionic, cationic, and amphoteric surfactants in various matrices. The Surfactant Plus column is compatible with LC-MS instrumentation | Acclaim Surfactant Plus data sheet |
Acclaim Explosives E2 columns | Specialty columns to comply with EPA Method 8330; baseline resolution of all 14 explosive residues targeted by the EPA | |
Acclaim Trinity Q1 columns | Excellent for trace analysis of diquat and paraquat | |
Acclaim Carbonyl columns | Separation of DNPH derivatives of aldehydes and ketones; including regulated methods U.S. EPA 554, EPA 8315, EPA 1667, EPA TO-11, and CARB 1004. | Acclaim Carbonyl data sheet |
Acclaim Carbamate columns | Separation of carbamate pesticides specified in U.S. EPA Method 531.2 | Acclaim Carbamate data sheet |
Acclaim AmG C18 columns | Reversed-phase separation of aminoglycoside antibiotics. | Acclaim AmG C18 data sheet |
Specifications for Acclaim application-specific columns | ||||||||
---|---|---|---|---|---|---|---|---|
Acclaim Organic Acid | Acclaim Surfactant | Acclaim Surfactant Plus | Acclaim Explosives E2 | Acclaim Carbonyl | Acclaim Carbamate | Acclaim AmG | Acclaim Trinity Q1 | |
End-capped | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Particle Shape | Spherical | Spherical | Spherical | Spherical | Spherical | Spherical | Spherical | Spherical |
Particle Size | 3 μm, 5 μm | 3 μm, 5 μm | 3 μm, 5 μm | 2.2 μm, 3 μm, 5 μm | 2.2 μm, 3 μm, 5 μm | 2.2 μm, 3 μm, 5 μm | 3 μm | 3 μm, 5 μm |
Average Pore Diameter | 120 Å | 120 Å | 120 Å | 300 Å | 120 Å | 120 Å | 300 Å | 300 Å |
Surface Area | 300 m2/g | 300 m2/g | 300 m2/g | 100 m2/g | 300 m2/g | 300 m2/g | 100 m2/g | 100 m2/g |
Column | Use for | Data sheet |
---|---|---|
Acclaim SEC-1000 and Acclaim SEC-300 | Separation of water-soluble polymers using resin based columns. | Acclaim SEC columns data sheet |
Specifications for Acclaim size exclusion columns (SEC) | ||
---|---|---|
Acclaim SEC-300 | Acclaim SEC-1000 | |
Substrate | Hydrophilic polymethacrylate resin | Hydrophilic polymethacrylate resin |
Particle Shape | Spherical | Spherical |
Particle Size | 5 μm | 7 μm |
Pore Size | 300 Å (multi-pore) | 1000 Å (multi-pore) |
Separation range for PEO* | 100 – 50,000 Daltons | 1,000 – 1,000,000 Daltons |
Exclusion limit for PEO* | 50,000 – 150,000 Daltons | 3,000,000 – 7,500,000 Daltons |
Related HPLC columns
Accucore HPLC columns
Solid core particles in Accucore HPLC columns deliver fast separations with superb resolution.
Hypersil GOLD HPLC columns
General-purpose columns for exceptional peak shape and accuracy in LC and MS applications.
Discover live and on-demand webinars that enable you to improve productivity, maintain compliance, and learn about the constantly evolving scientific landscape.
Resources
Literature
Thermo Scientific HPLC columns
Style Sheet for Global Design System
Style Sheet for Komodo Tabs